TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual 25-117 V2.0, 2007-07
ADC, V2.0
SW0TRSEL [6:4] rw SW0 Trigger Request Selection
This bit determines which trigger source will be used
for the ADCx SW0 trigger request input.
000
B
SW0TR = 0; no trigger function of SW0TR.
001
B
SW0TR is connected to GPTA0_OUT3.
010
B
SW0TR is connected to GPTA0_OUT11.
011
B
SW0TR is connected to GPTA0_OUT28.
100
B
SW0TR is connected to TOUT0.
101
B
SW0TR is connected to TOUT1.
110
B
SW0TR is connected to TOUT2.
111
B
SW0TR is connected to TOUT3.
QTRSEL [10:8] rw Queue Trigger Request Selection
This bit determines which trigger source will be used
for the ADCx queue trigger request input QTR.
000
B
QTR = 0; no trigger function of QTR.
001
B
QTR is connected to GPTA0_OUT3.
010
B
QTR is connected to GPTA0_OUT11.
011
B
QTR is connected to GPTA0_OUT28.
100
B
QTR is connected to TOUT0.
101
B
QTR is connected to TOUT1.
110
B
QTR is connected to TOUT2.
111
B
QTR is connected to TOUT3.
TTRSEL [14:12] rw Timer Trigger Request Selection
This bit determines which trigger source will be used
for the ADCx timer trigger request input TTR.
000
B
TTR = 0; no trigger function of TTR.
001
B
TTR is connected to GPTA0_OUT3.
010
B
TTR is connected to GPTA0_OUT11.
011
B
TTR is connected to GPTA0_OUT28.
100
B
TTR is connected to TOUT0.
101
B
TTR is connected to TOUT1.
110
B
TTR is connected to TOUT2.
111
B
TTR is connected to TOUT3.
Field Bits Type Description