TC1796
System Units (Vol. 1 of 2)
System Control Unit
User’s Manual 5-33 V2.0, 2007-07
SCU, V2.0
SW0TRSEL [6:4] rw SW0 Trigger Request Selection
This bit determines which trigger source will be used
for the SW0 trigger request input SW0TR of ADCx.
000
B
SW0TR is constant at 0 level (trigger function
switched off).
001
B
ROUT0 is connected to SW0TR.
010
B
ROUT1 is connected to SW0TR.
011
B
ROUT2 is connected to SW0TR.
100
B
TOUT0 is connected to SW0TR.
101
B
TOUT1 is connected to SW0TR.
110
B
TOUT2 is connected to SW0TR.
111
B
TOUT3 is connected to SW0TR.
QTRSEL [10:8] rw Queue Trigger Request Selection
This bit determines which trigger source will be used
for the queue trigger request input QTR of ADCx.
000
B
QTR is constant at 0 level (trigger function
switched off).
001
B
ROUT0 is connected to QTR.
010
B
ROUT1 is connected to QTR.
011
B
ROUT2 is connected to QTR.
100
B
TOUT0 is connected to QTR.
101
B
TOUT1 is connected to QTR.
110
B
TOUT2 is connected to QTR.
111
B
TOUT3 is connected to QTR.
TTRSEL [14:12] rw Timer Trigger Request Selection
This bit determines which trigger source will be used
for the timer trigger request input TTR of ADCx.
000
B
TTR is constant at 0 level (trigger function
switched off).
001
B
ROUT0 is connected to TTR.
010
B
ROUT1 is connected to TTR.
011
B
ROUT2 is connected to TTR.
100
B
TOUT0 is connected to TTR.
101
B
TOUT1 is connected to TTR.
110
B
TOUT2 is connected to TTR.
111
B
TOUT3 is connected to TTR.
Field Bits Type Description