TC1796
System Units (Vol. 1 of 2)
System Control Unit
User’s Manual 5-47 V2.0, 2007-07
SCU, V2.0
SCU_TCLR1
SCU Temperature Compensation 1 Level Register
(F000005C
H
) Reset Value: 02FF FFFF
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
THCOUNT THMAX1
rh rw
1514131211109876543210
THMED1 THMIN1
rw rw
Field Bits Type Description
THMIN1 [7:0] rw Minimum Threshold for Temp. Compensation 1
Driver level = Low or Min
THMED1 [15:8] rw Medium Threshold for Temp. Compensation 1
Driver level = High or Low
THMAX1 [23:16] rw Maximum Threshold for Temp. Compensation 1
Driver level = Max or High
THCOUNT [31:24] rh Threshold Counter
Returns the actual count value of the counter that
counts the f
POSC
clock pulses. THCOUNT is only
updated when temperature compensation is enabled
(TCE0 or TCE1 or both set).