EasyManua.ls Logo

Infineon Technologies TC1796 - Page 724

Infineon Technologies TC1796
2150 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC1796
System Units (Vol. 1 of 2)
Direct Memory Access Controller
User’s Manual 12-60 V2.0, 2007-07
DMA, V2.0
ME0SER 16 rh Move Engine 0 Source Error
This bit is set whenever a Move Engine 0 error occurred
during a source (read) move of a DMA transfer, or a
request could not been serviced due to the access
protection.
0
B
No Move Engine 0 source error has occurred.
1
B
A Move Engine 0 source error has occurred.
ME0DER 17 rh Move Engine 0 Destination Error
This bit is set whenever a Move Engine 0 error occurred
during a destination (write) move of a DMA transfer, or a
request could not been serviced due to the access
protection.
0
B
No Move Engine 0 destination error has occurred.
1
B
A Move Engine 0 destination error has occurred.
ME1SER 18 rh Move Engine 1 Source Error
This bit is set whenever a Move Engine 1 error occurred
during a source (read) move of a DMA transfer, or a
request could not been serviced due to the access
protection.
0
B
No Move Engine 1 source error has occurred.
1
B
A Move Engine 1 source error has occurred.
ME1DER 19 rh Move Engine 1 Destination Error
This bit is set whenever a Move Engine 1 error occurred
during a destination (write) move of a DMA transfer, or a
request could not been serviced due to the access
protection.
0
B
No Move Engine 1 destination error has occurred.
1
B
A Move Engine 1 destination error has occurred.
FPI0ER 20 rh SPB Error
This bit is set whenever a move that has been started by
the DMA/MLI master interface on FPI Bus interface 0
leads to an error.
0
B
No error occurred.
1
B
An error occurred on FPI Bus interface 0.
Field Bits Type Description