EasyManuals Logo

Infineon Technologies TC1796 User Manual

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #972 background imageLoading...
Page #972 background image
TC1796
System Units (Vol. 1 of 2)
Watchdog Timer
User’s Manual 16-34 V2.0, 2007-07
WDT, V2.0
WDTPR 5rhWatchdog Prewarning Mode Flag
0
B
Normal mode (default after reset)
1
B
The Watchdog is operating in Prewarning
Mode
This bit is set to 1 when a Watchdog error is detected.
The WDT has issued an NMI trap and is in
Prewarning Mode. A reset of the chip occurs after the
prewarning period has expired.
WDTTIM [31:16] rh WDT Value
Reflects the current content of the WDT.
0 [15:6] r Reserved
Read as 0.
Field Bits Type Description