TC1796
System Units (Vol. 1 of 2)
Watchdog Timer
User’s Manual 16-34 V2.0, 2007-07
WDT, V2.0
WDTPR 5rhWatchdog Prewarning Mode Flag
0
B
Normal mode (default after reset)
1
B
The Watchdog is operating in Prewarning
Mode
This bit is set to 1 when a Watchdog error is detected.
The WDT has issued an NMI trap and is in
Prewarning Mode. A reset of the chip occurs after the
prewarning period has expired.
WDTTIM [31:16] rh WDT Value
Reflects the current content of the WDT.
0 [15:6] r Reserved
Read as 0.
Field Bits Type Description