Remote control commands
R&S
®
RTE
1127User Manual 1326.1032.02 ─ 20
PROBe<m>:PMETer:VISibility....................................................................................... 1128
TRPRobe:PMETer:RESults:SINGle?.............................................................................. 1129
PROBe<m>:PMETer:RESults:SINGle?...........................................................................1129
TRPRobe:PMETer:RESults:COMMon?...........................................................................1129
PROBe<m>:PMETer:RESults:COMMon?....................................................................... 1129
TRPRobe:PMETer:RESults:DIFFerential?.......................................................................1129
PROBe<m>:PMETer:RESults:DIFFerential?....................................................................1129
TRPRobe:PMETer:RESults:NEGative?...........................................................................1130
PROBe<m>:PMETer:RESults:NEGative?....................................................................... 1130
TRPRobe:PMETer:RESults:POSitive?............................................................................1130
PROBe<m>:PMETer:RESults:POSitive?.........................................................................1130
PROBe<m>:SETup:MODE <Mode>
Select the action that is started when you press the micro button on the probe head.
See also: "Micro button action" on page 197.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<Mode> RCONtinuous | RSINgle | AUToset | AZERo | SEToffsettomean |
SITFile | NOACtion | FINDtriglevel | REPort | PROBemode |
PRSetup | PRINt
RCONtinuous
Run continuous: The acquisition is running as long as the probe
button is pressed.
RSINgle
Run single: Starts a defined number of acquisitions (same as
[RUN N× SINGLE] key).
AUTOSET
Starts the autoset procedure.
AZero
AutoZero: performs an automatic correction of the zero error.
SEToffsettomean
Set offset to mean: performs an automatic compensation for a
DC component of the input signal.
SITFile
Save Image To File:
Directs the display image to a file. The MMEMory:NAME com-
mand defines the file name. The file format is defined with
HCOPy:DEVice<m>:LANGuage.
NOACtion
Nothing is started on pressing the micro button.
FINDtriglevel
Sets the trigger level automatically to 0.5 * (MaxPeak – Min-
Peak). The function is not available for an external trigger
source.