Remote control commands
R&S
®
RTE
1837User Manual 1326.1032.02 ─ 20
TRIGger<m>:USBPd:BIT <Frame>, <Field>, <Bit>
TRIGger<m>:USBPd:FRAMe<n>:FLD<o>:BIT <BitState>
Sets the bit state of a field that only consists of one bit.
Suffix:
<m>
.
1..3
<n> *
<o> *
Specifies the field number within the frame.
Parameters:
<BitState> ONE | ZERO | DC
ONE
1
ZERO
0
DC
"Don't care" (DC) = X
*RST: DC
TRIGger<m>:USBPd:DMAX <Frame>, <Field>, <Data>
TRIGger<m>:USBPd:FRAMe<n>:FLD<o>:DMAX <DataMax>
Sets the end value of a data pattern range if TRIGger<m>:USBPd:FRAMe<n>:
FLD<o>:DMAX is set to INRange or OORange.
Suffix:
<m>
.
1..3
<n> *
Specifies the field number within the frame.
<o> *
Parameters:
<DataMax> Specifies the name of the generic trigger setting frame, see
BUS<m>:USBPd:RESult:FRAMe<n>:TYPE? on page 1844.
TRIGger<m>:USBPd:DMIN <Frame>, <Field>, <Data>
TRIGger<m>:USBPd:FRAMe<n>:FLD<o>:DMIN <DataMin>
Specifies the data pattern, or sets the start value of a data pattern range.
Suffix:
<m>
.
1..3
<n> *
Specifies the field number within the frame.
<o> *