Protocol analysis
R&S
®
RTE
666User Manual 1326.1032.02 ─ 20
Remote command:
TRIGger<m>:MILStd:DATA:DCONdition on page 1614
TRIGger<m>:MILStd:DATA:DMAX on page 1615
TRIGger<m>:MILStd:DATA:DMIN on page 1615
Data Index
The MIL-MIL-STD-1553 standard defines the length of a message to a series of up to
32 words. Data index sets the range within this series of the data words that is consid-
ered for the analysis. The data index setup consists of the condition and one or two
data index values.
"Condition"
Sets the comparison condition to a specific value or a range.
"Index Min/Index"
Specifies the value or sets the start value of a range.
"Index Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
TRIGger<m>:MILStd:DATA:ICONdition on page 1615
TRIGger<m>:MILStd:DATA:IMAX on page 1615
TRIGger<m>:MILStd:DATA:IMIN on page 1616
11-Bit Information
The 11-Bit information sets bits 9 to 19 if there is a command or status word. The 11-Bit
information consists of the condition and one or two 11-Bit information patterns.
In binary format, use the following characters: 1; 0; or X (do not care). To enter the pat-
tern in other formats use the bit pattern editor, see Chapter 13.1.5, "Bit pattern editor",
on page 521.
"Condition"
Sets the comparison condition to a specific value or a range.
"Info Min/Info"
Specifies the value or sets the start value of a range.
"Info Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".