Protocol analysis
R&S
®
RTE
845User Manual 1326.1032.02 ─ 20
Remote command:
SEARch:TRIGger:USB:WFRN on page 1824
SEARch:TRIGger:USB:FCONdition on page 1816
SEARch:TRIGger:USB:FMIN on page 1817
SEARch:TRIGger:USB:FMAX on page 1817
Payload check
Enables the search for a payload data pattern that meets specific conditions.
"Condition"
Sets the operator "any" or "equal" that allows to search for payload
data at any position or at a specified position.
"Position"
Available only if "Condition" (SEARch:TRIGger:USB:DPOPerator)
is set to equal. Specifies the position in which a special data pattern
is to be searched within the payload data packet.
"Data Condi-
tion"
Sets the operator ("equal" or "unequal", SEARch:TRIGger:USB:
DCONdition) to set a specific payload data pattern.
"Payload pat-
tern"
Specifies the payload data pattern that is to be searched.
Remote command:
SEARch:TRIGger:USB:WPAY on page 1825
SEARch:TRIGger:USB:DPOPerator on page 1815
SEARch:TRIGger:USB:DPOSition on page 1815
SEARch:TRIGger:USB:DCONdition on page 1815
SEARch:TRIGger:USB:PATT on page 1818
SC check
Searches for the selected Start (0) or Complete (1) SPLIT transaction endpoint, or X
(do not care).
Remote command:
SEARch:TRIGger:USB:WSTC on page 1826
SEARch:TRIGger:USB:STCO on page 1822
Port check
Enables the search for a port that meets specific conditions.
"Condition"
Defining a specific port number or a port number range requires to
set the operator to one of the following: equal, not equal, less than,
less than or equal, greater than, greater than or equal, in range, out
of range.
"Min"
Specifies a port number, or sets the start value of a port number
range.
"Max"
Sets the end value of a port number range if "Condition" (SEARch:
TRIGger:USB:PCONdition) is set to INRange or OORange.
Remote command:
SEARch:TRIGger:USB:WPOR on page 1825
SEARch:TRIGger:USB:PCONdition on page 1818
SEARch:TRIGger:USB:PMIN on page 1818
SEARch:TRIGger:USB:PMAX on page 1819
USB (option R&S