Module Operation
www.ti.com
1266
SPNU563AMarch 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
When an ECC error has been detected the following actions will be performed:
In all cases:
The corresponding error flag in the message handler status (MHDS) register is set and the faulty
message buffer is indicated. On ECC single-bit error equivalent information is available in the single-bit
error location (SBESTAT) register.
The error flag EIR.PERR in the error interrupt register is set and, if enabled, a module interrupt to the
CPU will be generated. An ECC single-bit error is indicated by the SBESTAT.SBE flag irrespective of
ECC single-bit error correction being enabled. Additionally an ECC single-bit error can generate an
interrupt to the CPU.
Additionally in specific cases of ECC multi-bit errors:
1. ECC multi-bit error during data transfer from input buffer RAM 1,2 message RAM
a. Transfer of header and/or data section and ECC multi-bit error occurs during header and/ or data
section transfer to message RAM:
MHDS.PIBF bit is set
MHDS.FMBD bit is set to indicate that MHDS.FMB(6-0) points to a faulty message buffer
MHDS.FMB(6-0) indicates the number of the faulty message buffer
Header and/or data section of the corresponding message buffer is updated
Transmission request for the corresponding message buffer is not set (no transfer to the
FlexRay bus)
b. Transfer of data section only and ECC multi-bit error occurs when reading header section of the
corresponding message buffer from the message RAM.
MHDS.PMR bit is set
MHDS.FMBD bit is set to indicate that MHDS.FMB(6-0) points to a faulty message buffer
MHDS.FMB(6-0) indicates the number of the faulty message buffer
The data section of the corresponding message buffer is not updated
Transmission request for the corresponding message buffer is not set (no transfer to the
FlexRay bus)
2. ECC multi-bit error during host CPU reading input buffer RAM 1,2
MHDS.PIBF bit is set
3. ECC multi-bit error during scan of header sections in message RAM
MHDS.PMR bit is set
MHDS.FMBD bit is set to indicate that MHDS.FMB(6-0) points to a faulty message buffer
MHDS.FMB(6-0) indicates the number of the faulty message buffer
Ignore message buffer (the transfer of the message buffer is skipped)
4. ECC multi-bit error during data transfer from message RAM to transient buffer RAM 1,2
MHDS.PMR bit is set
MHDS.FMBD bit is set to indicate that MHDS.FMB(6-0) points to the faulty message buffer
MHDS.FMB(6-0) indicates the number of the faulty message buffer
Frame not transmitted, frames already in transmission are invalidated by clearing the frame CRC
to 0
5. ECC multi-bit error during data transfer from transient buffer RAM 1,2 to protocol controller 1, 2
MHDS.PTBF1,2 bit is set
Frames already in transmission are invalidated by clearing the frame CRC to 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TMS570LC4357 and is the answer not in the manual?

Texas Instruments TMS570LC4357 Specifications

General IconGeneral
BrandTexas Instruments
ModelTMS570LC4357
CategoryMicrocontrollers
LanguageEnglish

Related product manuals