www.ti.com
EPC Control Registers
489
SPNU563A–March 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
Error Profiling Controller (EPC)
12.4.1 EPC REVID Register (EPCREVID)
Figure 12-2. EPC REVID Register (EPCREVID) (offset = 00h)
31 30 29 28 27 16
SCHEME Reserved FUNC
R-1 R-0 R-A0Ah
15 11 10 8 7 6 5 0
RTL MAJOR CUSTOM MINOR
R-0 R-0 R-0 R-0
LEGEND: R = Read only; -n = value after synchronous reset on system reset
Table 12-2. EPC REVID Register (EPCREVID) Field Descriptions
Bit Field Value Description
31-30 SCHEME 1 Identification scheme.
29-28 Reserved 0 Reserved. Reads return 0.
27-16 FUNC A0Ah Indicates functionally equivalent module family.
15-11 RTL 0 RTL version number.
10-8 MAJOR 0 Major revision number.
7-6 CUSTOM 0 Indicates device-specific implementation.
5-0 MINOR 0 Minor revision number.