TC1796
Peripheral Units (Vol. 2 of 2)
Micro Second Channel (MSC)
User’s Manual 21-51 V2.0, 2007-07
MSC, V2.0
RDIE [15:14] rw Receive Data Interrupt Enable
This bit field determines the enable conditions for the
receive data interrupt.
00
B
Interrupt generation disabled.
01
B
An interrupt is generated when data is received
and written into the upstream data registers
UDx (x = 0-3).
10
B
An interrupt is generated as with RDIE = 01
B
but only if the received data is not equal to 00
H
.
11
B
An interrupt is generated when data is received
and written into register UD3.
0 6, 10,
[31:16]
r Reserved
Read as 0; should be written with 0.
Field Bits Type Description