TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual 22-76 V2.0, 2007-07
MultiCAN, V2.0
SUSEN 8rwSuspend Enable
This bit makes it possible to set the CAN node into
Suspend Mode via OCDS (on chip debug support):
0
B
An OCDS suspend trigger is ignored by the CAN
node.
1
B
An OCDS suspend trigger disables the CAN node:
As soon as the CAN node becomes bus-idle or
bus-off, bit INIT is internally forced to 1 to disable
the CAN node. The actual value of bit INIT remains
unchanged.
Bit SUSEN is cleared via OCDS Reset.
0 [31:9],
5
r Reserved
Read as 0; should be written with 0.
Field Bits Type Description