EasyManua.ls Logo

Rohde & Schwarz RTE - Page 1411

Rohde & Schwarz RTE
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTE
1411User Manual 1326.1032.02 ─ 20
To export the measurement histogram, it must be enabled using MEASurement<m>:
STATistics:HISTogram.
To export the long term results, the long term measurement must be enabled using
MEASurement<m>:LTMeas[:STATe].
To export a track, the track must be enabled before. Track measurements require an
option, see "Enable (Track)" on page 389.
Parameters:
<ExportType> LONGterm | HISTogram | TRACk
LONGTERM = LONGterm, HISTOGRAM = HISTogram
*RST: HISTogram
Example: See "Exporting long-term measurement data to file"
on page 1059
Usage: Asynchronous command
EXPort:MEASurement:NAME <Path>
Sets the file name and path to save the long term or measurement histogram data to.
Parameters:
<Path> String with path and file name. The file extension defines the file
format: XML, CSV, or BIN.
Example: See "Exporting long-term measurement data to file"
on page 1059
Usage: Asynchronous command
EXPort:MEASurement:SAVE
Saves the long term or measurement histogram results to the file specified using
EXPort:MEASurement:NAME.
The measurement data can be exported as absolute or relative values, which is
defined using EXPort:HISTogram:INCidence.
Example:
See "Exporting long-term measurement data to file"
on page 1059
Usage: Event
EXPort:MEASurement:DATA?
Transfers the long term measurement data to the controlling computer. The data can
be used in MATLAB, for example. The transferred data are the same as the data writ-
ten to files.
Data management