Remote control commands
R&S
®
RTE
1494User Manual 1326.1032.02 ─ 20
ID
IDentifier: Sets the trigger to one specific identifier or an identi-
fier range. To set the identifier, use TRIGger<m>:CAN:
ICONdition, TRIGger<m>:CAN:IMIN, and TRIGger<m>:
CAN:IMAX.
IDDT
IDentifier and DaTa: Combination of identifier and data condi-
tions To set the identifier condition, use TRIGger<m>:CAN:
ICONdition, TRIGger<m>:CAN:IMIN, and TRIGger<m>:
CAN:IMAX.
To set the data condition, use TRIGger<m>:CAN:DCONdition,
TRIGger<m>:CAN:DMIN, and TRIGger<m>:CAN:DMAX.
ERRC
ERRor Condition: Define the error types with
TRIGger<m>:CAN:ACKerror,
TRIGger<m>:CAN:BITSterror,
TRIGger<m>:CAN:CRCerror,
TRIGger<m>:CAN:FORMerror,
TRIGger<m>:CAN:FDATa:SCERror on page 1500.
*RST:
STOF
TRIGger<m>:CAN:FDATa:STANdard <Standard>
Selects the CAN standard. Use ANY if the standard of the signal is unknown.
The setting is available in CAN FD option R&S RTE-K9.
Parameters:
<Standard> ANY | CAN | CANFd
*RST: CAN
TRIGger<m>:CAN:FTYPe <FrameType>
Selects the CAN frame type if TRIGger<m>:CAN:TYPE is set to FTYP (frame type) or
ID (identifier).
For data and remote frames, the identifier format has to be set with TRIGger<m>:
CAN:ITYPe.
See also: "Frame type" on page 568
Parameters:
<FrameType> ANY | DATA | REMote | ERRor | OVERload
Available values depend on the CAN standard and on the
TRIGger<m>:CAN:TYPE setting:
Remote frames are not available in the CAN FD protocol.
If the trigger type is set to FTYP (frame type), you can set the
values DATA | REMote | ERRor | OVERload.
Protocols