Remote control commands
R&S
®
RTE
1564User Manual 1326.1032.02 ─ 20
IDDT
IDentifier and DaTa: triggers on the decoded frame content, on
header and payload data.
For all settings that are not needed for the trigger condition,
make sure to set its condition to OFF.
Indicator bits: see TRIGger<m>:FLXRay:NUFRame
Frame identifier: sets the trigger to one specific frame ID or an
identifier range. To set the identifier, use TRIGger<m>:
FLXRay:FCONdition, TRIGger<m>:FLXRay:FMIN, and
TRIGger<m>:FLXRay:FMAX.
Payload length: trigger on the number of words in the payload
segment. To set the payload length, use TRIGger<m>:
FLXRay:PCONdition, TRIGger<m>:FLXRay:PMIN, and
TRIGger<m>:FLXRay:PMAX.
Cycle count: trigger on the number of the current FlexRay cycle.
To set the cycle count, use TRIGger<m>:FLXRay:CENable,
TRIGger<m>:FLXRay:CMIN, TRIGger<m>:FLXRay:CMAX,
and TRIGger<m>:FLXRay:CSTep.
Data position: sets the position of the data bit pattern within the
payload segment. To set the data position, use TRIGger<m>:
FLXRay:DPOPerator, TRIGger<m>:FLXRay:DPOSition,
and TRIGger<m>:FLXRay:DPTO.
Data bit pattern: sets the data bit pattern to be found in the pay-
load segment. The starting point of the pattern is defined by the
data position. To set the bit pattern, use TRIGger<m>:FLXRay:
DCONdition, TRIGger<m>:FLXRay:DMIN, and
TRIGger<m>:FLXRay:DMAX.
SYMBol
Triggers on a symbol or wakeup pattern. Set the required sym-
bol with TRIGger<m>:FLXRay:SYMBol
ERRC
ERRor Condition: triggers on one or more errors that are detec-
ted in the decoded data. Use TRIGger<m>:FLXRay:
BSSerror, TRIGger<m>:FLXRay:FESerror, TRIGger<m>:
FLXRay:FSSerror, and TRIGger<m>:FLXRay:PCRCerror.
*RST:
STOF
TRIGger<m>:FLXRay:PLPReamble <PayloadPreamble>
Triggers on the payload preamble indicator bit that indicates a Network Management
Vector in the payload segment.
Parameters:
<PayloadPreamble> ONE | ZERO | DC
Bit value: 1, 0, or X (don't care)
*RST: DC