Remote control commands
R&S
®
RTE
1563User Manual 1326.1032.02 ─ 20
To trigger on a serial bus, make sure that:
TRIGger<m>:SOURce[:SELect] is set to SBUS.
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
Decoding is enabled: BUS<m>[:STATe] is set to ON.
TRIGger<m>:FLXRay:TYPE......................................................................................... 1563
TRIGger<m>:FLXRay:PLPReamble...............................................................................1564
TRIGger<m>:FLXRay:NUFRame...................................................................................1565
TRIGger<m>:FLXRay:SYFRame...................................................................................1565
TRIGger<m>:FLXRay:STFRame................................................................................... 1565
TRIGger<m>:FLXRay:FCONdition.................................................................................1565
TRIGger<m>:FLXRay:FMIN..........................................................................................1566
TRIGger<m>:FLXRay:FMAX.........................................................................................1566
TRIGger<m>:FLXRay:PCONdition.................................................................................1566
TRIGger<m>:FLXRay:PMIN..........................................................................................1566
TRIGger<m>:FLXRay:PMAX.........................................................................................1567
TRIGger<m>:FLXRay:CENable.....................................................................................1567
TRIGger<m>:FLXRay:CMIN..........................................................................................1567
TRIGger<m>:FLXRay:CMAX........................................................................................ 1567
TRIGger<m>:FLXRay:CSTep........................................................................................ 1568
TRIGger<m>:FLXRay:DPOPerator................................................................................ 1568
TRIGger<m>:FLXRay:DPOSition...................................................................................1568
TRIGger<m>:FLXRay:DPTO.........................................................................................1568
TRIGger<m>:FLXRay:DCONdition.................................................................................1569
TRIGger<m>:FLXRay:DMIN..........................................................................................1569
TRIGger<m>:FLXRay:DMAX........................................................................................ 1569
TRIGger<m>:FLXRay:SYMBol...................................................................................... 1569
TRIGger<m>:FLXRay:BSSerror.....................................................................................1570
TRIGger<m>:FLXRay:FESerror.....................................................................................1570
TRIGger<m>:FLXRay:FSSerror.....................................................................................1570
TRIGger<m>:FLXRay:HCRCerror..................................................................................1570
TRIGger<m>:FLXRay:PCRCerror..................................................................................1570
TRIGger<m>:FLXRay:TYPE <Type>
Selects the trigger type for FlexRay analysis.
Parameters:
<Type> STOF | IDDT | SYMBol | ERRC
STOF
STart Of Frame: triggers on the first rising edge after the trans-
mission start sequence (TSS).
Protocols