Application of the ECAP Module
www.ti.com
1942
SPNU563AMarch 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
Enhanced Capture (eCAP) Module
33.3.3.1 Code Snippet for CAP Mode Delta Time, Rising Edge Trigger
// Code snippet for CAP mode Delta Time, Rising edge trigger
// Initialization Time
//=======================
// ECAP module 1 config
ECap1Regs.ECCTL1.bit.CAP1POL = EC_RISING;
ECap1Regs.ECCTL1.bit.CAP2POL = EC_RISING;
ECap1Regs.ECCTL1.bit.CAP3POL = EC_RISING;
ECap1Regs.ECCTL1.bit.CAP4POL = EC_RISING;
ECap1Regs.ECCTL1.bit.CTRRST1 = EC_DELTA_MODE;
ECap1Regs.ECCTL1.bit.CTRRST2 = EC_DELTA_MODE;
ECap1Regs.ECCTL1.bit.CTRRST3 = EC_DELTA_MODE;
ECap1Regs.ECCTL1.bit.CTRRST4 = EC_DELTA_MODE;
ECap1Regs.ECCTL1.bit.CAPLDEN = EC_ENABLE;
ECap1Regs.ECCTL1.bit.PRESCALE = EC_DIV1;
ECap1Regs.ECCTL2.bit.CAP_APWM = EC_CAP_MODE;
ECap1Regs.ECCTL2.bit.CONT_ONESHT = EC_CONTINUOUS;
ECap1Regs.ECCTL2.bit.SYNCO_SEL = EC_SYNCO_DIS;
ECap1Regs.ECCTL2.bit.SYNCI_EN = EC_DISABLE;
ECap1Regs.ECCTL2.bit.TSCTRSTOP = EC_RUN; // Allow TSCTR to run
// Run Time ( e.g. CEVT1 triggered ISR call)
//==========================================
// Note: here Time-stamp directly represents the Period value.
Period4 = ECap1Regs.CAP1; // Fetch Time-Stamp captured at T1
Period1 = ECap1Regs.CAP2; // Fetch Time-Stamp captured at T2
Period2 = ECap1Regs.CAP3; // Fetch Time-Stamp captured at T3
Period3 = ECap1Regs.CAP4; // Fetch Time-Stamp captured at T4