www.ti.com
SCI Interrupts
1727
SPNU563AMarch 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
Serial Communication Interface (SCI) Module
30.3.4 Error Interrupts
The following error detection features are supported with Interrupt by the SCI module:
Parity errors (PE)
Frame errors (FE)
Break Detect errors (BRKDT)
Overrun errors (OE)
If any of these errors (PE, FE, BRKDT, OE) is flagged, an interrupt for the flagged errors will be generated
if enabled. A message is valid for both the transmitter and the receiver if there is no error detected until
the end of the frame. Each of these flags is located in the receiver status (SCIFLR) register. Further
details on these flags are explained in SCIFLR register description.
The SCI module supports following 7 interrupts as seen in Table 30-1.
(1)
Offset 1 is the highest priority. Offset 16 is the lowest priority.
Table 30-1. SCI Interrupts
Offset
(1)
Interrupt
0 Reserved
1 Wakeup
2 Reserved
3 Parity error
4 Reserved
5 Reserved
6 Frame error
7 Break detect error
8 Reserved
9 Overrun error
10 Reserved
11 Receive
12 Transmit
13 - 15 Reserved