Table 33-9. ECAP Control Register 1 (ECCTL1) Field Descriptions (continued)
Bits Field Value Description
2 CAP2POL Capture Event 2 Polarity select.
0 Capture Event 2 triggered on a rising edge (RE).
1 Capture Event 2 triggered on a falling edge (FE).
1 CTRRST1 Counter Reset on Capture Event 1.
0 Do not reset counter on Capture Event 1 (absolute time stamp).
1 Reset counter after Event 1 time-stamp has been captured (used in difference mode operation).
0 CAP1POL Capture Event 1 Polarity select.
0 Capture Event 1 triggered on a rising edge (RE).
1 Capture Event 1 triggered on a falling edge (FE).