EasyManuals Logo

Texas Instruments TMS570LC4357 User Manual

Texas Instruments TMS570LC4357
2208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1355 background imageLoading...
Page #1355 background image
www.ti.com
FlexRay Module Registers
1355
SPNU563AMarch 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.2.2.8 Timer 0 Configuration Register (T0C)
This absolute timer specifies, in terms of cycle count and macrotick, the point in time when the timer 0
interrupt occurs. The timer 0 interrupt generates a non maskable interrupt signal on CC_tint0.
Timer 0 can be activated as long as the POC is either in NORMAL_ACTIVE state or in
NORMAL_PASSIVE state. Timer 0 is deactivated when leaving NORMAL_ACTIVE state or
NORMAL_PASSIVE state except for transitions between the two states.
Before reconfiguration of the timer, the timer has to be halted first by writing bit T0RC to 0.
Figure 26-124 and Table 26-103 illustrate this register.
Figure 26-124. Timer 0 Configuration Register (T0C) [offset_CC = 44h]
31 30 29 16
Reserved TOMO
R-0 R/W-0
15 14 8 7 2 1 0
Rsvd TOCC Reserved TOMS TORC
R-0 R/W-0 R-0 R/W-0 R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 26-103. Timer 0 Configuration Register (T0C) Field Descriptions
Bit Field Value Description
31-30 Reserved 0 Reads return 0. Writes have no effect.
29-16 TOMO 0-3FFFh Timer 0 macrotick offset. Configures the macrotick offset from the beginning of the cycle where the
interrupt is to occur. The Timer 0 interrupt occurs at this offset for each cycle in the cycle set.
15 Reserved 0 Reads return 0. Writes have no effect.
14-8 TOCC 0-FFh Timer 0 cycle code. The 7-bit timer 0 cycle code determines the cycle set used for generation of
the timer 0 interrupt.
7-2 Reserved 0 Reads return 0. Writes have no effect.
1 TOMS Time 0 mode select.
0 Single-shot mode.
1 Continuous mode.
0 TORC Timer 0 run control.
0 Timer 0 is halted.
1 Timer 0 is running.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TMS570LC4357 and is the answer not in the manual?

Texas Instruments TMS570LC4357 Specifications

General IconGeneral
BrandTexas Instruments
ModelTMS570LC4357
CategoryMicrocontrollers
LanguageEnglish

Related product manuals