EasyManuals Logo

Enterasys C3G124-24 User Manual

Enterasys C3G124-24
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
set system utilization
3-10 Basic Configuration
This example shows how to display the system’s overall memory usage:
C3(ro)->show system utilization storage
Storage Utilization:
Type Description Size(Kb) Available (Kb)
---------------------------------------------------------------
RAM RAM device 262144 97173
Flash Images, Config, Other 31095 8094
This example shows how to display information about the processes running on the system. Only
partial output is shown.
C3(ro)->show system utilization process
Switch:1 CPU:1
TID Name 5Sec 1Min 5Min
----------------------------------------------------------
c157930 ipMapForwardingTask 3.60% 3.02% 3.48%
cc70000 RMONTask 0.00% 0.00% 0.00%
ccb0b60 SNMPTask 34.80% 34.06% 31.78%
d4847a0 tEmWeb 0.00% 0.03% 0.01%
d4ca360 hapiRxTask 3.20% 4.80% 5.00%
dec8600 lvl7TaskUtilMonitorTas 0.40% 0.40% 0.40%
eb74120 bcmRX 2.00% 2.91% 4.48%
eb7fbc8 bcmLINK.0 0.40% 0.22% 0.32%
f00c9a0 bcmTX 0.00% 0.33% 0.53%
f027648 bcmCNTR.0 0.00% 0.00% 0.03%
f034858 bcmL2X.0 0.00% 0.02% 0.04%
set system utilization
Use this command to set the threshold for sending CPU utilization notification messages.
Syntax
set system utilization threshold threshold
Parameters
Defaults
The default threshold value is 80%.
Mode
Switch command, read-write.
Usage
This command sets the percentage of system CPU utilitization that will cause a trap notification to
be sent. After the threshold has been exceeded, additional notifications will be sent once a minute
until the utilization has dropped back below the threshold.
Example
This example sets the CPU utilization threshold to 75%.
threshold threshold Specifies a threshold value in 1/10 of a percent. Valid range is 1 to 1000.
A value of 0 disables utilization notification messages.