clear dot1x auth-config
32-24 Authentication and Authorization Configuration
Examples
This example shows how to enable reauthentication control on ports ge.1.1-3:
C3(su)->set dot1x auth-config reauthenabled true ge.1.1-3
This example shows how to set the 802.1X quiet period to 120 seconds on ports ge.1.1-3:
C3(su)->set dot1x auth-config quietperiod 120 ge.1.1-3
clear dot1x auth-config
Use this command to reset 802.1X authentication parameters to default values on one or more
ports.
Syntax
clear dot1x auth-config [authcontrolled-portcontrol] [maxreq] [quietperiod]
[reauthenabled] [reauthperiod] [servertimeout] [supptimeout] [txperiod] [port-
string]
Parameters
Defaults
If no parameters are specified, all authentication parameters will be reset.
If port-string is not specified, parameters will be set on all ports.
Mode
Switch command, read-write.
Examples
This example shows how to reset the 802.1X port control mode to auto on all ports:
C3(su)->clear dot1x auth-config authcontrolled-portcontrol
This example shows how to reset reauthentication control to disabled on ports ge.1.1-3:
C3(su)->clear dot1x auth-config reauthenabled ge.1.1-3
authcontrolled-
portcontrol
(Optional) Resets the 802.1X port control mode to auto.
maxreq (Optional) Resets the maximum requests value to 2.
quietperiod (Optional) Resets the quiet period value to 60 seconds.
reauthenabled (Optional) Resets the reauthentication control state to disabled (false).
reauthperiod (Optional) Resets the reauthentication period value to 3600 seconds.
servertimeout (Optional) Resets the server timeout value to 30 seconds.
supptimeout (Optional) Resets the authentication supplicant timeout value to 30
seconds.
txperiod (Optional) Resets the transmission period value to 30 seconds.
port-string (Optional) Resets settings on specific port(s). For a detailed description of
possible port-string values, refer to “Port String Syntax Used in the CLI” on
page 11-1.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys C3G124-24 and is the answer not in the manual?

Enterasys C3G124-24 Specifications

General IconGeneral
BrandEnterasys
ModelC3G124-24
CategorySwitch
LanguageEnglish

Related product manuals