set cdp hold-time
Enterasys C3 Configuration Guide 10-5
Example
This example shows how to set the CDP interval frequency to 15 seconds:
C3(su)->set cdp interval 15
set cdp hold-time
Use this command to set the hold time value for CDP discovery protocol configuration messages.
Syntax
set cdp hold-time hold-time
Parameters
Defaults
None.
Mode
Switch command, read-write.
Example
This example shows how to set CDP hold time to 60 seconds:
C3(su)->set cdp hold-time 60
clear cdp
Use this command to reset CDP discovery protocol settings to defaults.
Syntax
clear cdp {[state] [port-state port-string] [interval] [hold-time] [auth-code]}
Parameters
Defaults
At least one optional parameter must be entered.
hold-time Specifies the hold time value for CDP messages in seconds.Valid values are
from 15 to 600.
state (Optional) Resets the global CDP state to auto-enabled.
port-state port-string (Optional) Resets the port state on specific port(s) to auto-enabled.
interval (Optional) Resets the message frequency interval to 60 seconds.
hold-time (Optional) Resets the hold time value to 180 seconds.
auth-code (Optional) Resets the authentication code to 16 bytes of 00 (00-00-00-
00-00-00-00-00).