Configuring System Logging show logging default
19-6
show logging default
Use this command to display the Syslog server default values.
Syntax
show logging default
Parameters
None.
Defaults
None.
Mode
Switch command, read-only.
Example
This command shows how to display the currently configured Syslog server default values. For an
explanation of the command output, refer back to Table 19-1 on page 19-4.
C3(su)->show logging default
Facility Severity Port
-----------------------------------------
Defaults: local4 warning(5) 514
set logging default
Use this command to set logging default values.
Syntax
set logging default {[facility facility] [severity severity] port port]}
Parameters
facility facility Specifies the default facility name. Valid values are: local0 to local7.
severity severity Specifies the default logging severity level. Valid values and
corresponding levels are:
1 — emergencies (system is unusable)
2 — alerts (immediate action required)
3 — critical conditions
4 — error conditions
5 — warning conditions
6 — notifications (significant conditions)
7 — informational messages
8 — debugging messages
port port Specifies the default UDP port the client uses to send to the server.