clear arpinspection limit
Enterasys C3 Configuration Guide 23-29
clear arpinspection limit
Use this command to return the DAI rate limiting values to their default values for a port or range
of ports.
Syntax
clear arpinspection limit port port-string
Parameters
Defaults
Rate = 15 packets per second
Burst Interval = 1 second
Mode
Switch mode, read-write.
Usage
Use the set arpinspection limit command to change the values of the rate limit and burst interval.
Use the show arpinspection ports command to display the currently configured rate limits.
Example
This example returns the DAI rate limiting values to their defaults for port ge.1.1.
C3(su)->clear arpinspection limit port ge.1.1
clear arpinspection statistics
Use this command to clear all dynamic ARP inspection statistics.
Syntax
clear arpinspection statistics
Parameters
None.
Defaults
None.
Mode
Switch command, read-write.
Example
This example clears all DAI statistics from the switch.
port-string Specifies the ports on which to return the rate limiting values to
defaults.