set ip address
3-4 Basic Configuration
Mode
Switch command, read-only.
Example
This example shows how to display the system IP address and subnet mask:
C3(su)->show ip address
Name Address Mask
---------------- ---------------- ----------------
host 10.42.13.20 255.255.0.0
set ip address
Use this command to set the system IP address, subnet mask and default gateway.
Syntax
set ip address ip-address [mask ip-mask] [gateway ip-gateway]
Parameters
Defaults
If not specified, ip-mask will be set to the natural mask of the ip-address and ip-gateway will be set to
the ip-address.
Mode
Switch command, read-write.
Usage
Parameters must be entered in the order shown (host IP, then mask, then gateway) for the
command to be accepted.
Example
This example shows how to set the system IP address to 10.1.10.1 with a mask of 255.255.128.0:
C3(su)->set ip address 10.1.10.1 mask 255.255.128.0
Note: The C3 does not support the ability for a user to configure the host's gateway to be a local
routed interface IP. The host's gateway must exist on a different device in the network if one is
configured.
ip-address Sets the IP address for the system. For Enterasys C3 systems, this is the IP
address of the management switch as described in “About Enterasys C3
Switch Operation in a Stack” on page 2-1.
mask ip-mask (Optional) Sets the system’s subnet mask.
gateway ip-gateway (Optional) Sets the system’s default gateway (next-hop device).