EasyManua.ls Logo

Enterasys C3G124-24 - Set Rmon Event Properties; Show Rmon Event Output Details

Enterasys C3G124-24
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set rmon event properties
21-14 RMON Configuration
set rmon event properties
Use this command to configure an RMON event entry, or to create a new event entry with an
unused event index number.
Syntax
set rmon event properties index [description description] [type {none | log | trap
| both}] [community community] [owner owner]
Parameters
Defaults
If description is not specified, none will be applied.
If not specified, type none will be applied.
If owner is not specified, monitor will be applied.
Mode
Switch command, read-write.
Table 21-3 show rmon event Output Details
Output Field What It Displays...
Index Index number for this event entry.
Owner Text string identifying who configured this entry.
Status Whether this event entry is enabled (valid) or disabled.
Description Text string description of this event.
Type Whether the event notification will be a log entry, and SNMP trap, both, or none.
Community SNMP community name if message type is set to trap.
Last Time Sent When an event notification matching this entry was sent.
index Specifies an index number for this entry. Maximum number of entries is
100. Maximum value is 65535.
description
description
(Optional) Specifies a text string description of this event.
type none | log |
trap | both
(Optional) Specifies the type of RMON event notification as: none, a log
table entry, an SNMP trap, or both a log entry and a trap message.
community
community
(Optional) Specifies an SNMP community name to use if the message
type is set to trap. For details on setting SNMP traps and community
names, refer to ā€œCreating a Basic SNMP Trap Configurationā€ on
page 12-35.
owner owner (Optional) Specifies the name of the entity that configured this entry.