Page #528 background image
set rmon alarm properties
21-10 RMON Configuration
set rmon alarm properties
Use this command to configure an RMON alarm entry, or to create a new alarm entry with an
unused alarm index number.
Syntax
set rmon alarm properties index [interval interval] [object object] [type
{absolute | delta}] [startup {rising | falling | either}] [rthresh rthresh]
[fthresh fthresh] [revent revent] [fevent fevent] [owner owner]
Parameters
Table 21-2 show rmon alarm Output Details
Output Field What It Displays...
Index Index number for this alarm entry.
Owner Text string identifying who configured this entry.
Status Whether this event entry is enabled (valid) or disabled.
Variable MIB object to be monitored.
Sample Type Whether the monitoring method is an absolute or a delta sampling.
Startup Alarm Whether alarm generated when this entry is first enabled is rising, falling, or either.
Interval Interval in seconds at which RMON will conduct sample monitoring.
Rising Threshold Minimum threshold for causing a rising alarm.
Falling Threshold Maximum threshold for causing a falling alarm.
Rising Event Index Index number of the RMON event to be triggered when the rising threshold is
crossed.
Falling Event Index Index number of the RMON event to be triggered when the falling threshold is
crossed.
index Specifies an index number for this entry. Maximum number or entries is
50. Maximum value is 65535.
interval interval (Optional) Specifies an interval (in seconds) for RMON to conduct sample
monitoring.
object object (Optional) Specifies a MIB object to be monitored.
Note: This parameter is not mandatory for executing the command, but
must be specified in order to enable the alarm entry configuration.
type absolute |
delta
(Optional) Specifies the monitoring method as: sampling the absolute
value of the object, or the difference (delta) between object samples.