Factory Default Settings
1-2 Introduction
• Remotely using an SNMP management station.
• In-band through a Telnet connection.
• In-band using the Enterasys NetSight
®
management application.
• Remotely using WebView™, Enterasys Networks’ embedded web server application.
The Installation Guide for your Enterasys C3 device provides setup instructions for connecting a
terminal or modem to the switch.
Factory Default Settings
The following tables list factory default settings available on the Enterasys C3 switch.
Table 1-1 Default Settings for Basic Switch Operation
Feature Default Setting
Switch Mode Defaults
CDP discovery protocol Auto enabled on all ports.
CDP authentication code Set to 00-00-00-00-00-00-00-00
CDP hold time Set to 180 seconds.
CDP interval Transmit frequency of CDP messages set to 60 seconds.
Cisco discovery protocol Auto enabled on all ports.
Cisco DP hold time Set to 180 seconds.
Cisco DP interval timer Set to 60 seconds.
Community name Public.
Console (serial) port
required settings
Baud rate: 9600
Data bits: 8
Flow control: disabled
Stop bits: 1
Parity: none
DHCP server Disabled.
EAPOL Disabled.
EAPOL authentication
mode
When enabled, set to auto for all ports.
GARP timer Join timer set to 20 centiseconds; leave timer set to 60 centiseconds; leaveall
timer set to 1000 centiseconds.
GVRP Globally enabled. Disabled per port.
History buffer size 20 lines.
IEEE 802.1 authentication Disabled.
IGMP snooping Disabled. When enabled, query interval is set to 260 seconds and response
time is set to 10 seconds.
IP mask and gateway Subnet mask set to 0.0.0.0; default gateway set to 0.0.0.0.
IP routes No static routes configured.
Jumbo frame support Enabled on all ports.