Event Group Commands
Enterasys C3 Configuration Guide 21-13
Event Group Commands
Purpose
To display and clear RMON events, and to configure RMON event properties.
Commands
show rmon event
Use this command to display RMON event entry properties.
Syntax
show rmon event [index]
Parameters
Defaults
If index is not specified, information about all RMON entries will be displayed.
Mode
Switch command, read-only.
Example
This example shows how to display RMON event entry 3:
C3(rw)->show rmon event 3
Index 3
----------------
Owner = Manager
Status = valid
Description = STP Topology change
Type = log-and-trap
Community = public
Last Time Sent = 0 days 0 hours 0 minutes 37 seconds
Table 21-3 provides an explanation of the command output.
For information about... Refer to page...
show rmon event 21-13
set rmon event properties 21-14
set rmon event status 21-15
clear rmon event 21-15
index (Optional) Displays RMON properties and log entries for a specific entry
index ID.

Table of Contents