show mac agetime
Enterasys C3 Configuration Guide 18-11
Defaults
If no parameters are specified, all MAC addresses for the device will be displayed.
Mode
Switch command, read-only.
Example
This example shows how to display MAC address information for ge.3.1:
C3(su)->show mac port ge.3.1
MAC Address FID Port Type
----------------- ---- ------------- --------
00-09-6B-0F-13-E6 15 ge.3.1 Learned
MAC Address VLAN Port Type Status Egress Ports
----------------- ---- ------------- ------- ------- ---------------------------
01-01-23-34-45-56 20 any mcast perm ge.3.1
Table 18-3 provides an explanation of the command output.
show mac agetime
Use this command to display the timeout period for aging learned MAC entries.
Syntax
show mac agetime
Parameters
None.
Table 18-3 show mac Output Details
Output Field What It Displays...
MAC Address MAC addresses mapped to the port(s) shown.
FID Filter database identifier.
Port Port designation.
Type Address type. Valid types are:
Learned
•Self
Management
Other (this will include any static MAC locked addresses as described in
Configuring MAC Locking” on page 32-61).
mcast (multicast)
VLAN The VLAN ID configured for the multicast MAC address.
Status The status of the multicast address.
Egress Ports The ports which have been added to the egress ports list.