set txqmonitor minrate Transmit Queue Monitoring Configuration
Enterasys C3 Configuration Guide 9-3
Defaults
The default value is 0, meaning that disabled ports will remain disabled until cleared manually or
until their next link state transition.
Mode
Switch command, read-write.
Usage
When the downtime is configured as 0, disabled ports can be manually enabled using the clear
txqmonitor down command (page 9-4).
Example
This example sets the downtime to 3600 seconds.
C3(su)-> set txqmonitor downtime 3600
set txqmonitor minrate
Use this command to set the minimum rate (in packets per second) of transmitted packets in a
sampling interval.
Syntax
set txqmonitor minrate rate
Parameters
Defaults
One packet per second.
Mode
Switch command, read-write.
Example
This example sets the minimum rate of packets per second per sampling interval to 6.
C3(su)-> set txqmonitor minrate 6
set txqmonitor threshold
Use this command to set the transmit queue monitoring threshold levels for triggering actions
applied to a stalled port.
Syntax
set txqmonitor threshold { [logging | ignorepause | disableinterface] value }
rate The number of packets per second that must be transmitted per
sampling interval, if packets exist on the port’s transmit queues.
The default value is 1 packet per second.