EasyManua.ls Logo

Enterasys C3G124-24 - Set Console Baud; Set Console Vt100

Enterasys C3G124-24
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set console baud
3-26 Basic Configuration
Defaults
If no parameters are specified, all settings will be displayed.
Mode
Switch command, read-only.
Example
This example shows how to display all console settings:
C3(su)->show console
vt100 terminal mode disabled
Baud Flow Bits StopBits Parity
------ ------- ---- ---------- ------
9600 Disable 8 1 none
set console baud
Use this command to set the console port baud rate.
Syntax
set console baud rate
Parameters
Defaults
None.
Mode
Switch command, read-write.
Example
This example shows how to set the console port baud rate to 19200:
C3(su)->set console baud 19200
set console vt100
Use this command to enable or disable VT100 terminal mode.
Syntax
set console vt100 {enable | disable)
flowcontrol (Optional) Displays the type of flow control.
parity (Optional) Displays the type of parity.
stopbits (Optional) Displays the number of stop bits.
vt100 (Optional) Displays the state of VT100 mode.
rate Sets the console baud rate. Valid values are: 1200, 2400, 4800, 9600, 19200, 38400,
57600, and 115200.