set spantree spanguardtimeout
13-28 Spanning Tree Configuration
Defaults
None.
Mode
Switch command, read-only.
Example
This example shows how to display the SpanGuard timeout setting:
C3(su)->show spantree spanguardtimeout
Spanguard timeout: 300
set spantree spanguardtimeout
Use this command to set the amount of time (in seconds) an edge port will remain locked by the
SpanGuard function.
Syntax
set spantree spanguardtimeout timeout
Parameters
Defaults
None.
Mode
Switch command, read-write.
Example
This example shows how to set the SpanGuard timeout to 600 seconds:
C3(su)->set spantree spanguardtimeout 600
clear spantree spanguardtimeout
Use this command to reset the Spanning Tree SpanGuard timeout to the default value of 300
seconds.
Syntax
clear spantree spanguardtimeout
Parameters
None.
timeout Specifies a timeout value in seconds. Valid values are 0 to 65535.
A value of 0 will keep the port locked until manually unlocked. The default
value is 300 seconds.