Stacking Configuration and Management Commands
Enterasys C3 Configuration Guide 2-5
stack and then copy the C2 firmware to the C3 switch using the set switch copy-fw command
(page 2-9). After copying the C2 firmware to the C3 switch, you must reset the stack.
Switch Manager
It is recommended that a SecureStack C3 switch be made the manager of a mixed stack. Use the set
switch movemanagement command (page 2-10) to change the manager unit.
Stacking Configuration and Management Commands
Purpose
To review, individually configure and manage switches in a Enterasys C3 stack.
Commands
show switch
Use this command to display information about one or more units in the stack.
Syntax
show switch [status] [unit]
Parameters
For information about... Refer to page...
show switch 2-5
show switch switchtype 2-7
show switch stack-ports 2-8
set switch 2-8
set switch copy-fw 2-9
set switch description 2-10
set switch movemanagement 2-10
set switch member 2-11
clear switch member 2-11
set switch stack-ports length 2-12
clear switch stack-ports length 2-13
show switch stack-ports length 2-13
status (Optional) Displays power and administrative status information for one
or more units in the stack.
unit (Optional) Specifies the unit(s) for which information will display.