clear spantree mstmap
Enterasys C3 Configuration Guide 13-15
Parameters
Defaults
If sid is not specified, FID(s) will be mapped to Spanning Tree 0.
Mode
Switch command, read-write.
Example
This example shows how to map FID 3 to SID 2:
C3(su)->set spantree mstmap 3 sid 2
clear spantree mstmap
Use this command to map a FID back to SID 0.
Syntax
clear spantree mstmap fid
Parameters
Defaults
If fid is not specified, all SID to FID mappings will be reset.
Mode
Switch command, read-write.
Example
This example shows how to map FID 2 back to SID 0:
C3(su)->clear spantree mstmap 2
show spantree vlanlist
Use this command to display the Spanning Tree ID(s) assigned to one or more VLANs.
Syntax
show spantree vlanlist [vlan-list]
fid Specifies one or more FIDs to assign to the MST. Valid values are 1 - 4093,
and must correspond to a VLAN ID created using the set vlan command.
sid sid (Optional) Specifies a Multiple Spanning Tree ID. Valid values are 1 - 4094,
and must correspond to a SID created using the set msti command.
fid Specifies one or more FIDs to reset to 0.