area virtual-link hello-interval
Enterasys C3 Configuration Guide 31-19
Mode
Router OSPFv3 configuration: C3(su)->router(Config-router)#
Usage
Use the no form of this command to return a configured value to the default of 40 seconds.
Example
This example configures a dead interval of 60 seconds for the specified virtual interface.
C3(su)->router(Config-router)# area 20 virtual-link 2.2.2.2 dead-interval 60
area virtual-link hello-interval
This command configures the hello interval for the specified OSPFv3 virtual interface.
Syntax
area areaid virtual-link neighborid hello-interval seconds
no area areaid virtual-link neighborid hello-interval
Parameters
Defaults
The default hello interval is 10 seconds.
Mode
Router OSPFv3 configuration: C3(su)->router(Config-router)#
Usage
Use the no form of this command to return a configured value to the default value of 10 seconds.
Example
This example configures a hello interval of 30 seconds for the specified OSPFv3 virtual interface.
C3(su)->router(Config-router)# area 20 virtual-link 2.2.2.2 hello-interval 30
areaid Specifies the area ID in IP address format (dotted-quad) or as a decimal
value.
neighborid Specifies the virtual link neighbor by means of its router ID. The router
ID must be entered in 32-bit dotted-quad notation.
seconds Specifies the value of the hello interval in seconds. The range is from 1
to 65535 seconds.