show spantree operedge
13-44 Spanning Tree Configuration
Parameters
Defaults
None.
Mode
Switch command, read-write.
Example
This example shows how to reset ge.1.11 as a non-edge port:
C3(su)->clear spantree adminedge ge.1.11
show spantree operedge
Use this command to display the Spanning Tree edge port operating status for a port.
Syntax
show spantree operedge [port port-string]
Parameters
Defaults
If port-string is not specified, edge port operating status will be displayed for all Spanning Tree
ports.
Mode
Switch command, read-only.
Example
This example shows how to display the edge port status for ge.2.7:
C3(rw)->show spantree operedge port ge.2.7
Port ge.2.7 has a Port Oper Edge of Edge-Port
port-string Specifies port(s) on which to reset edge port status. For a detailed
description of possible port-string values, refer to ā€œPort String Syntax Used
in the CLIā€ on page 11-1.
port port-string Displays edge port operating status for specific port(s).