set pwa initialize
Enterasys C3 Configuration Guide 32-85
Usage
PWA will use a guest password and guest user name to grant network access with default policy
privileges to users without established login names and passwords.
Example
This example shows how to enable PWA guest networking with RADIUS authentication:
C3(su)->set pwa guestnetworking authradius
set pwa initialize
Use this command to initialize a PWA port to its default unauthenticated state.
Syntax
set pwa initialize [port-string]
Parameters
Defaults
If port-string is not specified, all ports will be initialized.
Mode
Switch command, read-write.
Example
This example shows how to initialize ports ge.1.5-7:
C3(su)->set pwa initialize ge.1.5-7
set pwa quietperiod
Use this command to set the amount of time a port will remain in the held state after a user
unsuccessfully attempts to log on to the network.
Syntax
set pwa quietperiod time [port-string]
Parameters
port-string (Optional) Initializes specific port(s). For a detailed description of possible
port-string values, refer to “Port String Syntax Used in the CLI” on
page 11-1.
time Specifies quiet time in seconds.
port-string (Optional) Sets the quiet period for specific port(s). For a detailed
description of possible port-string values, refer to “Port String Syntax Used
in the CLI” on page 11-1.