set switch copy-fw
Enterasys C3 Configuration Guide 2-9
Parameters
Defaults
None.
Mode
Switch command, read-write.
Examples
This example shows how to assign priority 3 to switch 5:
C3(su)->set switch 5 priority 3
This example shows how to renumber switch 5 to switch 7:
C3(su)->set switch 5 renumber 7
set switch copy-fw
Use this command to replicate the code image file from the management switch to other
switch(es) in the stack.
Syntax
set switch copy-fw [destination-system unit]
Parameters
Defaults
If destination-system is not specified, the management image file will be replicated to all switches
in the stack.
Mode
Switch command, read-write.
Example
This example shows how to replicate the management image file to all switches in the stack:
C3(su)->set switch copy-fw
Are you sure you want to copy firmware? (y/n) y
Code transfer completed successfully.
unit Specifies a unit number for the switch. Value can range from 1 to 8.
priority value Specifies a priority value for the unit. Valid values are 1 to 15 with higher
values assigning higher priority.
renumber newunit Specifies a new number for the unit.
Note: This number must be a previously unassigned unit ID number.
destination-system
unit
(Optional) Specifies the unit number of unit on which to copy the
management image file.