Loading...
show spantree autoedge
Enterasys C3 Configuration Guide 13-33
Mode
Switch command, read-write.
Example
This example clears the legacy path cost to 802.1t values.
C3(rw)->clear spantree legacypathcost
show spantree autoedge
Use this command to display the status of automatic edge port detection.
Syntax
show spantree autoedge
Parameters
None.
Defaults
None.
Mode
Switch command, read-only.
Example
This example shows how to display the status of the automatic edge port detection function:
C3(rw)->show spantree autoedge
autoEdge is currently enabled.
set spantree autoedge
Use this command to enable or disable the automatic edge port detection function.
Syntax
set spantree autoedge {disable | enable}
Parameters
Defaults
None.
Mode
Switch command, read-write.
disable | enable Disables or enables automatic edge port detection.