set lldp med-fast-repeat
Enterasys C3 Configuration Guide 10-25
Example
This example sets the minimum interval between LLDP traps to 10 seconds.
C3(rw)->set lldp trap-interval 10
set lldp med-fast-repeat
Network connectivity devices transmit only LLDP TLVs in LLDPDUs until they detect that an
LLDP-MED endpoint device has connected to a port. At that point, the network connectivity
device starts sending LLDP-MED TLVs at a fast start rate on that port. Use this command to set the
number of successive LLDPDUs (with LLDP-MED TLVs) to be sent for one complete fast start
interval.
Syntax
set lldp med-fast-repeat count
Parameters
Defaults
None.
Mode
Switch command, read-write.
Example
This example sets the number of fast start LLDPDUs to be sent to 4.
C3(rw)->set lldp med-fast-repeat 4
set lldp port status
Use this command to enable or disable transmitting and processing received LLDPDUs on a port
or range of ports.
Syntax
set lldp port status {tx-enable | rx-enable | both | disable} port-string
Parameters
count Specifies the number of fast start LLDPDUs to be sent when an
LLDP-MED endpoint device is detected. Value can range from 1 to
10. Default is 3.
tx-enable Enables transmitting LLDPDUs on the specified ports.
rx-enable Enables receiving and processing LLDPDUs from remote systems on
the specified ports.
both Enables both transmitting and processing received LLDPDUs on the
specified ports.
disable Disables both transmitting and processing received LLDPDUs on the
specified ports.