clear tacacs session
36-8 TACACS+ Configuration
The service name and attribute-value pairs can be any character string, and are determined by
your TACACS+ server configuration.
Since a task ID is associated with each accounting session, if there is a failover to a backup server,
the accounting information will still be associated with the correct session using the task ID.
Examples
This example configures the service requested by the TACACS+ client as the service name “basic.”
C3(rw)->set tacacs session authorization service basic
This example maps the read-write access privilege level to an attribute named “priv-lvl” with the
value of 5 configured on the TACACS+ server.
C3(rw)->set tacacs session authorization read-write priv-lvl 5
This example enables TACACS+ session accounting.
C3(rw)->set tacacs session accounting enable
clear tacacs session
Use this command to return the TACACS+ session authorization settings to their default values.
Syntax
clear tacacs session authorization {[service]|[read-only]|[read-write] |
[super-user]}
Parameters
Defaults
At least one of the session authorization parameters must be specified.
Mode
Switch command, Read-Write.
Examples
This example shows how to return the service name to the default of “exec.”
C3(rw)->clear tacacs session authorization service
This example shows how to return all the session authorization parameters to their default values.
C3(rw)->clear tacacs session authorization service read-only read-write super-
user
authorization Clears the TACACS+ session authorization parameters.
service Clears the TACACS+ session authorization service name to the default
value of “exec.”
read-only Clears the TACACS+ session authorization read-only attribute-value
pair to their default values of “priv-lvl” and 0.
read-write Clears the TACACS+ session authorization read-write attribute-value
pair to their default values of “priv-lvl” and 1.
super-user Clears the TACACS+ session authorization super-user attribute-value
pair to their default values of “priv-lvl” and 15.