show logging buffer Configuring System Logging
Enterasys C3 Configuration Guide 19-13
show logging buffer
Use this command to display the last 256 messages logged.
Syntax
show logging buffer
Parameters
None.
Defaults
None.
Mode
Switch command, read-only, if security profile = normal.
Switch command, super-user, if security profile = c2
Example
This example shows an example of the output displayed with the show logging buffer command.
The type of information displayed depends on your logging settings.
C3(su)->show logging buffer
<165>Sep 4 07:43:09 10.42.71.13 CLI[5]User:rw logged in from 10.2.1.122 (telnet)
<165>Sep 4 07:43:24 10.42.71.13 CLI[5]User: debug failed login from 10.4.1.100
(telnet)
show logging interface
Use this command to display the interface used for the source IP address of the system logging.
Syntax
show logging interface
Parameters
None.
Defaults
None.
Mode
Switch mode, read-only.
Example
This example displays the output of this command. In this case, the IP address assigned to
loopback interface 1 will be used as the source IP address of the system logging.
C3(rw)->show logging interface
loopback 1 192.168.10.1