Page #96 background imageLoading...
Page #96 background image
Downloading a Firmware Image
3-30 Basic Configuration
12. In your teminal emulation program, set the terminal baud rate to 9600.
HyperTerminal: File > Properties > Configure > Bits per Second > Apply > OK > OK
TeraTerm: Setup > Serial port > Baud rate > OK
13. Press ENTER so the switch will complete the baud rate change and display a fresh prompt.
[Boot Menu] 1
14. Type 1 to start the new operational code. A message similar to the following displays:
Operational Code Date: Tue Jun 29 08:34:05 2012
Uncompressing.....
15. After the switch comes back up, log in and confirm that the new image has been detected and
is now running. You can use either the “show boot system” command or the “dir” command.
C5(rw)->show boot system
Current system image to boot: c5-series_06.61.xx
C5(rw)->
Reverting to a Previous Image
In the event that you need to downgrade to a previous version of code, you can do so by
completing the following steps as described in this chapter.
1. Save your running configuration with the save config command.
2. Make a copy of the current configuration with the show config outfile configs/filename
command. Use the dir command to confirm that the file was created.
3. If desired, copy the file to a remote TFTP server with the copy command:
copy configs/filename tftp://server_ipaddr/filename
4. Load your previous version of code on the device, as described in “Downloading a Firmware
Image” (page 3-27).
5. Set this older version of code to be the boot code with the set boot system command (page 3-
31). When the system asks if you want to reset the device, specify no (n).
6. Reload the saved configuration onto the device with the configure command, described on
page 3-40.
7. Reboot the system using the reset command (page 3-47).
Caution: Before reverting to a previous image, always back up your configuration by saving it to a
file (show config outfile on page 3-39). You can then copy the file to a remote location (copy on
page 3-41).
Note: You will not be able to peform these steps remotely unless you have remote console support.
Caution: If you do not follow the steps above, you may lose remote connectivity to the switch.

Table of Contents