1020 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
33 :TRIGger Commands
:TRIGger:DELay:ARM:SLOPe
(see page 1276)
Command Syntax
:TRIGger:DELay:ARM:SLOPe <slope>
<slope> ::= {NEGative | POSitive}
The :TRIGger:DELay:ARM:SLOPe command specifies rising (POSitive) or falling
(NEGative) for the arming edge in the Edge Then Edge trigger.
Query Syntax
:TRIGger:DELay:ARM:SLOPe?
The :TRIGger:DELay:ARM:SLOPe? query returns the current arming edge slope
setting.
Return Format
<slope><NL>
<slope> ::= {NEG | POS}
See Also "Introduction to :TRIGger Commands" on page 1007
":TRIGger:DELay:ARM:SOURce" on page 1021
":TRIGger:DELay:TDELay:TIME" on page 1022