712 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
29 :SBUS<n> Commands
:SBUS<n>:A429:SPEed
(see page 1276)
Command Syntax
:SBUS<n>:A429:SPEed <speed>
<speed> ::= {LOW | HIGH}
The :SBUS<n>:A429:SPEed command specifies the signal speed:
LOW — 12.5 kb/s.
HIGH — 100 kb/s.
Query Syntax
:SBUS<n>:A429:SPEed?
The :SBUS<n>:A429:SPEed? query returns the current ARINC 429 signal speed
setting.
Return Format
<speed><NL>
<speed> ::= {LOW | HIGH}
Errors "-241, Hardware missing" on page 1235
See Also "Introduction to :SBUS<n> Commands" on page 697
":SBUS<n>:MODE" on page 701
":SBUS<n>:A429:SIGNal" on page 710
":SBUS<n>:A429:FORMat" on page 709
":SBUS<n>:A429:SOURce" on page 711