:SBUS<n>:SPI:SOURce:DATA
(see page 1276)
Command Syntax
:SBUS<n>:SPI:SOURce:DATA <source>
<source> ::= {CHANnel<n> | EXTernal} for the DSO models
<source> ::= {CHANnel<n> | DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
The :SBUS<n>:SPI:SOURce:DATA command sets the source for the SPI serial
MOSI data.
This command is the same as the :SBUS<n>:SPI:SOURce:MOSI command.
Query Syntax
:SBUS<n>:SPI:SOURce:DATA?
The :SBUS<n>:SPI:SOURce:DATA? query returns the current source for the SPI
serial MOSI data.
Return Format
<source><NL>
See Also "Introduction to :TRIGger Commands" on page 1007
":SBUS<n>:SPI:SOURce:MOSI" on page 859
":SBUS<n>:SPI:SOURce:MISO" on page 858
":SBUS<n>:SPI:SOURce:CLOCk" on page 856
":SBUS<n>:SPI:SOURce:FRAMe" on page 857
":SBUS<n>:SPI:TRIGger:PATTern:MISO:DATA" on page 860
":SBUS<n>:SPI:TRIGger:PATTern:MOSI:DATA" on page 862
":SBUS<n>:SPI:TRIGger:PATTern:MISO:WIDTh" on page 861
":SBUS<n>:SPI:TRIGger:PATTern:MOSI:WIDTh" on page 863