:TRIGger Commands 33
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 1057
:TRIGger:RUNT:POLarity
(see page 1276)
Command Syntax
:TRIGger:RUNT:POLarity <polarity>
<polarity> ::= {POSitive | NEGative | EITHer}
The :TRIGger:RUNT:POLarity command sets the polarity for the runt trigger:
• POSitive — positive runt pulses.
• NEGative — negative runt pulses.
• EITHer — either positive or negative runt pulses.
Query Syntax
:TRIGger:RUNT:POLarity?
The :TRIGger:RUNT:POLarity? query returns the runt trigger polarity.
Return Format
<polarity><NL>
<polarity> ::= {POS | NEG | EITH}
See Also • "Introduction to :TRIGger Commands" on page 1007
• ":TRIGger:MODE" on page 1016
• ":TRIGger:LEVel:HIGH" on page 1014
• ":TRIGger:LEVel:LOW" on page 1015
• ":TRIGger:RUNT:SOURce" on page 1059